Insulation calculator

Depth and bags of blown-in insulation, or packs of batts, to reach your R-value.

Tip: feet in the first box, inches in the second (leave it empty for whole feet). Working in meters? Switch to m / cm at the top.

40 ft30 ftR-38
Estimated depth
15.2inches of blown fiberglass for R-38

Enter the ft² per bag from the coverage chart for R-38 to get a count.

  • Area1,200 ft²
  • R-value per inch (assumed)2.5
  • Depth for R-3815.2 in, only at 2.5 R per inch
  • Typical targetR-38 to R-60 in most US attics

Depth is an estimate from a typical R-per-inch. Each product prints its own chart of bags (or packs) per area and the settled depth needed for each R-value. Use that chart: it is what the installer and inspector go by.

Related calculators

Insulation is chosen by R-value, its resistance to heat flow. This calculator shows how deep each type needs to be to reach your target R-value, and counts bags or packs from the coverage printed on the product's label.

Worked example: a 40 × 30 ft attic to R-38 with blown fiberglass

  1. Attic floor: 40 × 30 = 1,200 ft².
  2. At about R-2.5 per inch, R-38 needs 38 ÷ 2.5 = 15.2 in of blown fiberglass.
  3. Find the R-38 row on the bag's chart. If it says, for example, 40 ft² per bag, enter 40: 1,200 ÷ 40 = 30 bags.
  4. Cellulose at about R-3.5 per inch would need about 11 in for the same R-38.

Before you start

  • Check what's there: measure existing insulation depth; you only add what's missing.
  • Seal air leaks first around pipes, wires, lights and the attic hatch.
  • Keep vents open: use baffles at the eaves so insulation doesn't block soffit vents.
  • Clearances: keep insulation away from recessed lights and chimneys unless they're rated for contact.

Approximate R per inch

TypeR per inch (approx.)Depth for R-38
Blown fiberglass2.2–2.7about 15 in
Blown cellulose3.2–3.8about 11 in
Fiberglass batts2.9–3.8about 12 in

Common mistakes

  • Compressing batts. Squashed insulation loses R-value.
  • Trusting depth alone. The bag chart's settled depth and bags per area are what reach the R-value.
  • Covering soffit vents, which traps moisture in the attic.

Questions people ask

How much attic insulation do I need?

ENERGY STAR recommends R-38 to R-60 for most US attics, depending on climate.

How many bags of blown insulation for 1,000 ft²?

It depends on the product and R-value. Read the bag chart's ft² per bag for your R-value and divide.

Can I add insulation on top of old insulation?

Usually yes, if the old insulation is dry and not moldy. Don't add a vapor barrier between layers.

Sources and limits

Last checked 25 November 2026. References: ENERGY STAR: insulation R-values. Results are estimates: product labels, your supplier and your local code come first. How we calculate · Report a mistake