Radiators are sold by their heat output, in BTU per hour or watts. Too small and the room never warms up; too big and you've paid for a radiator that spends most of its time throttled back. This calculator uses the common UK rule of thumb: room volume in cubic feet, times a factor for the type of room, then adjusted for north-facing walls, patio doors and double glazing.
Worked example: a 4 m × 3.5 m living room
- Room volume: 4 × 3.5 × 2.4 m = 33.6 m³, which is 1,187 ft³.
- Living room factor: 1,187 × 5 = 5,933 BTU/h.
- Double glazing takes off 10%: 5,933 × 0.9 = 5,340 BTU/h, about 1,565 W.
- North-facing as well? Add 15%: 5,340 × 1.15 ≈ 6,140 BTU/h. Pick a radiator rated at or just above the final figure.
How to measure the room
- Length and width at floor level, wall to wall, in metres. Ignore small alcoves; add big ones as their own volume.
- Ceiling height matters: a 2.7 m Victorian ceiling needs about 12% more heat than a 2.4 m modern one.
- Open-plan spaces: work out the whole space as one room and split the output over two or more radiators.
- Check the radiator's rating is quoted at ΔT50, the standard UK figure for gas boiler systems.
Room factors used
| Room | Multiply cubic feet by | Usual temperature |
|---|---|---|
| Living or dining room | 5 | 21 °C |
| Bathroom | 5 (we use the living room factor) | 22 to 23 °C |
| Bedroom | 4 | 16 to 18 °C |
| Kitchen, hall, landing | 3 | 16 to 18 °C |
Adjustments and when to go bigger
- North-facing: +15%. The room gets little winter sun.
- French or patio doors: +20%. Large glazed doors lose heat quickly.
- Double glazing: −10%, on by default. Turn it off for single-glazed rooms.
- Heat pumps run water at lower temperatures, so radiators give roughly half their ΔT50 rating. Ask your installer for a room-by-room heat-loss figure.
Common mistakes
- Measuring floor area only. Radiator sizing depends on volume, so the ceiling height counts.
- Comparing outputs at different ΔT ratings. A radiator listed at ΔT60 looks bigger on paper than the same one at ΔT50.
- Fitting one huge radiator in a long room. Two smaller ones at each end heat it more evenly.
Questions people ask
What size radiator do I need?
Multiply the room's volume in cubic feet by 5 for a living room, 4 for a bedroom or 3 for a kitchen or hall, then adjust for windows and aspect. A 4 × 3.5 m living room with a 2.4 m ceiling and double glazing needs about 5,300 BTU/h (1,565 W).
How do I convert BTU to watts?
Divide BTU per hour by 3.412. 5,000 BTU/h is about 1,465 W.
How many BTU do I need for a bedroom?
A 3 × 3 m bedroom with a 2.4 m ceiling and double glazing needs about 2,750 BTU/h (806 W) by this rule of thumb.
Is a bigger radiator better?
Up to a point. A slightly oversized radiator heats the room faster and suits lower flow temperatures, but a very oversized one costs more and needs a thermostatic valve to stop the room overheating.
Can I use this for a heat pump?
Only as a first rough figure. Heat pumps need a proper heat-loss calculation, and radiators give less heat at the lower water temperatures they use.